Pelco DSSRV Network Video Recorder
Siemens FC1012 12-zone conventional unit
Siemens FC1008 8-zone conventional unit
Siemens FC1004 4-zone conventional unit
Siemens FC1002 2-zone conventional unit
Base for Synova 300 series detectors Conventional Siemens SO320
Heat detector ( maximum) Conventional Siemens HI322C
Heat detector ( rate of rise and maximum) Conventional Siemens HI320C
Smoke detector‚ Conventional multi-sensor Siemens OH320C
Optical smoke detector Conventional Siemens OP320C
See all items
Average User Review
There is no review for this company
Write a review
Language:
English
Indonesia
Registration Date:
Apr. 29, 2008
Last Updated:
Apr. 24, 2012
Products Catalog
Select
and click
Inquiry Now
or
Add to Basket
or
Put on Product Partner
Clear All
-
Select All
Show
9
15
36
items per page
Gallery
List
Pelco DSSRV Network....
[May. 23, 2012 11:07:10]
• 280 Mbps to support IP and analog video
• Supports up to 128 IP Camera Streams; up to 64 Analog Cameras
• Optimized to Support Pre-Installed DS NVs Software
• Records H.264, ....
Siemens FC1012 12....
[May. 23, 2012 10:42:10]
Conventional line 12
Transmission output contact 2 x 30 VDC / 1 A
Supervised output 2 x 24 VDC / 0.5 A
Control output 18 x 24 VDC / 40 mA
Control input 6
Mains voltage 115.......
Siemens FC1008 8....
[May. 23, 2012 10:38:05]
Conventional line 8
Transmission output contact 2 x 30 VDC / 1 A
Supervised output 2 x 24 VDC / 0.5 A
Control output 14 x 24 VDC / 40 mA
Control input 6
Mains voltage 115.......
Siemens FC1004 4....
[May. 23, 2012 10:30:36]
Conventional line 4
Transmission output contact 2 x 30 VDC / 1 A
Supervised output 2 x 24 VDC / 0.5 A
Control output 7 x 24 VDC / 40 mA
Control input 3
Mains voltage 115.......
Siemens FC1002 2....
[May. 23, 2012 10:29:36]
Conventional line 2
Transmission output contact 2 x 30 VDC / 1 A
Supervised output 2 x 24 VDC / 0.5 A
Control output 5 x 24 VDC / 40 mA
Control input 3
Mains voltage 115.......
Base for Synova 300....
Cable capacity 0.2... 1.5 mm2
Color white‚ zRAL 9010
Delivery unit 6 pieces
Accessories SOA322 Base attachment for surface
mounting
TP320 Detector locking device
Heat detector ( ....
Operating voltage 16... 28 VDC
Quiescent current max. 100 NA
Operating temperature -10... + 50 ° C
Protection category IP44
Standard EN54-5: A2
Color white‚ zRAL 9010 ( can....
Heat detector ( rate....
Operating voltage 16... 28 VDC
Quiescent current max. 100 NA
Operating temperature -10... + 50 ° C
Protection category IP44
Standard EN 54-5: A1R
Color white‚ zRAL 9010 ( can....
Smoke detector‚ ....
Operating voltage 16... 28 VDC
Operating current no smoke max. 100 NA
with smoke max. 170 NA
Operating temperature -10... + 55 ° C
Protection category IP44
Standard EN 54-7
....
Optical smoke....
Operating voltage 16... 28 VDC
Operating current no smoke max. 100 NA
with smoke max. 170 NA
Operating temperature -10... + 55 ° C
Protection category IP44
Standard EN 54-7
....
Manual call point....
Communication protocol FDnet/ C-NET
Operating temperature -25... + 70 ° C
Storage temperature -30... + 75 ° C
Relative humidity L95 % ( no condensation)
Protection category....
Sounder base....
Communication protocol C-NET
Operating voltage 12... 33 VDC
Quiescent current 150 ¼ A
Alarm current 1.2 mA
Cable capacity 0.2... 1.6 mm2
Number of sounds 11
Sound intensity....
Detector base....
Cable capacity 0.2... 1.6 mm2
Dimensions ( Ø x H) 117 x 23 mm
Color white‚ zRAL 9010
Accessories FDBZ291 Designation plate
RS720 Detector base seal
DBZ1190-AA Micro terminal
....
Addressable Heat....
Communication protocol C-NET
Operating voltage 12... 33 VDC
Quiescent current z200 NA
Ext. alarm indicator 2
Operating temperature -10... + 50 ° C
Storage temperature -30... ....
Addressable Heat....
Communication protocol C-NET
Operating voltage 12... 33 VDC
Quiescent current z200 NA
Ext. alarm indicator 2
Operating temperature -10... + 50 ° C
Storage temperature -30... ....
Addressable Optical....
Communication protocol C-NET
Operating voltage 12... 33 VDC
Quiescent current z220 NA
Ext. alarm indicator 2
Operating temperature -10... + 50 ° C
Storage temperature -30... ....
Addressable Multi....
Communication protocol C-NET
Operating voltage 12... 33 VDC
Quiescent current z230 NA
Ext. alarm indicator 2
Operating temperature -10... + 50 ° C
Storage temperature -30... ....
Siemens Fire Alarm....
Number of addresses max. 1512
Number of detector lines Loop with loop extension -> 4 loops
or 8 stub lines
C-NET -> max. 20 ( 4 per line card)
Programmable input/ output max.....
Siemens Fire Alarm....
Number of addresses max. 504
Number of detector lines 4 ( 8) loops or 8 ( 16) stub lines
Programmable input/ output 12
Relay outputs 1x RT alarm
1x RT fault
Supervised output....
Siemens Fire Alarm....
Number of addresses max. 252
Number of detector lines 2 ( 4) loops or 4 ( 8) stub lines
Programmable input/ output 8
Relay outputs 1 x RT alarm
1 x RT fault
Supervised output....
Clear All
-